HOME
PRODUCTS
CONTACTS
CAREER
ABOUT US


GP 150 (UL listed)

PROPERTY

TEST METHOD

TEST CONDITION

UNIT

DATA

Melt flow index

ASTM D1238

200 oC, 5 kg

g/10 min

8.0

Izod notched impact

ASTM D256

1/4" at 23 o C

1/4" at 73.4 o F

kg-cm/cm

ft-lb/in

 

 

Tensile strength

ASTM D638

23 o C

73.4 o F

kg/cm 2

psi x10 3

443

6.30

Flexural strength

ASTM D790

23 o C

73.4 o F

kg/cm 2

psi x10 3

844

12.00

Flexural modulus

ASTM D790

23 o C

73.4 o F

x10 4 kg/cm 2

psi x10 5

3.23

4.59

Rockwell hardness

ASTM D785

1/4" at 23 o C

L-scale

82

Heat distortion

temperature

ASTM D648

(non annealing)

1/4" at 18.6  kg/cm 2

1/4" at 264 psi

o C

o F

93

199

Vicat softening

temperature

ASTM D1525

1/8" at 1 kg

1/8" at 2.20 lbs

o C

o F

100

212

FEATURES

APPLICATIONS

Injection grade (General Purpose)

Cosmetic cases, gifts, premiums, stationery, cassette tapes, refrigerator parts such as food trays, egg trays

Remark:  The values presented on the above are typical laboratory average and to be used as an approximate guideline and subject to change without notice.